CAP

Cold Atmospheric Plasma (CAP) Jet System

The Cold Atmospheric Plasma (CAP) Jet System​ is a non-contact, room-temperature plasma platform developed by Metathermo for biomedical research. Based on an improved dielectric barrier discharge (DBD) architecture and driven by a high-frequency AC power supply, the system uses high-purity helium to generate a stable, centimeter-long plasma jet at atmospheric pressure—without any vacuum environment. It supports both in vitro culture-medium activation (PAM) and in vivo tumor intervention via Metathermo’s proprietary intra-tissue needle. Validated by Jiangnan University Medical School, the platform significantly suppresses triple-negative breast cancer cells and inhibits tumor growth in bearing mice, making it a promising physical therapy tool for plasma medicine.

Product Image

Core Capabilities

  • Improved DBD & Laminar Jet Discharge The reactor adopts a helical ground electrode with an inverted conical quartz tube. Optimized quartz flow and electrode structure lower ignition voltage (≤ 0.23 kV) and stabilize a filamentary-discharge-suppressed, laminar jet for safe biological contact.
  • Metathermo Intra-Tissue Needle A proprietary dual-needle nested structure delivers plasma deep into tissue while venting reactive byproducts through the inter-needle gap. No extra exhaust incision is required, solving deep delivery and safe venting simultaneously.
  • Truly Cold Atmospheric Plasma (CAP) The jet maintains ≤ 25 °C even after 5-min exposure at ≤ 0.6 kV. The quartz surface stays slightly warm, ensuring no burn risk for in vitro cell cultures and in vivo animal models.
  • Human-Safe Electrical Boundary Validated via a human-impedance mock circuit: peak safety current ≤ 1.24 mA and mock-body voltage ≤ 1.83 V (far below the IEC 50 V limit), enabling compliant biomedical operation.
  • In Vitro & In Vivo Ready • In vitro: 1.5 L/min He flow for plasma-activated medium (PAM) and cell suppression. • In vivo: ≤ 0.22 L/min for intratumoral CAP delivery in subcutaneous xenograft models.
  • Controllable Active Species (OES-Characterized) Jet enriched with N₂, NOₓ, OH radicals, and He metastable atoms. Characterized by Mechelle ME5000 optical emission spectroscopy for mechanistic biochemistry.
  • Validated Antitumor Efficacy & Ferroptosis Mechanism SUM149 triple-negative breast cancer survival drops to ~20% after 24 h PAM; intratumoral CAP suppresses tumor growth in Balb/c nude mice. Mechanism clarified via mitochondrial shrinkage, GPX4 down-regulation, and Fer-1 reversal (ferroptosis).

Key Specifications

Item Specification
Discharge structure Improved DBD (helical ground electrode + inverted conical quartz tube)
Drive power High-frequency AC supply (Suman CTP-2000K), 8.8 kHz
Working gas High-purity helium (He)
Gas flow In vitro: 1.5 L/min; In vivo: ≤ 0.22 L/min
Ignition voltage ≤ 0.23 kV with Metathermo intra-tissue needle (≈ 50% lower than early version)
Jet length ≥ 11 mm without needle; stable discharge maintained with needle attached
Jet temperature ≤ 25 °C (5-min exposure at ≤ 0.6 kV)
Peak safety current ≤ 1.24 mA through human-impedance mock circuit at 0.6 kV
Safety voltage ≤ 1.83 V across mock body (IEC limit: 50 V)
Main active species N₂, NOₓ, OH radicals, He metastable atoms
High-voltage module Suman CTP-2000K high-frequency AC source
Discharge head Quartz tube + tungsten steel HV electrode + helical copper ground electrode
Gas control Precision flow meter, continuous He adjustment
Safety interface Human-impedance mock circuit for real-time V/I monitoring

Technical Highlights

  • From “quasi-DBD” to True Safe DBD: electrode and quartz-flow optimization cut ignition voltage and stabilize laminar jet discharge
  • Genuinely Cold Plasma: quartz surface only slightly warm after 30 min; core jet < 25 °C, no burn risk
  • Metathermo Intra-Tissue Needle: solves the conflict between “deep plasma delivery” and “byproduct venting” with a dual-lumen design
  • Validated Antitumor Efficacy: SUM149 TNBC survival dropped to ~20% after 24 h PAM; intratumoral CAP suppressed growth in Balb/c nude mice with normal body-weight gain
  • Mechanism Clarified: Ferroptosis: mitochondrial shrinkage, reduced cristae, GPX4 down-regulation; ferroptosis inhibitor Fer-1 reverses killing
  • OES-Characterized Chemistry: Mechelle ME5000 confirms NOₓ / OH abundance for biochemical mechanistic studies

Typical Applications

  • In Vitro Cancer Research: PAM preparation, triple-negative breast cancer cell suppression, ferroptosis mechanism studies
  • In Vivo Tumor Therapy: intratumoral CAP intervention in subcutaneous xenograft mice
  • Plasma Medicine Mechanisms: ROS / lipid-peroxide dynamics, mitochondrial function, Western-blot analysis
  • Safety Parameter Calibration: voltage / current / temperature boundary tests under human-impedance simulation
  • Reactive Species Spectroscopy: OES quantification of NOₓ, OH, N₂, and He metastables
  • Teaching & Demonstration: intuitive visualization of atmospheric cold-plasma discharge and biomedical potential